Roll load cell
Easy to assemble, overload protection, internal amplifier capability 4-20mA / 0-10V, for bearings diameter 28, 32, 35, 40, 42 mm
Click to enlarge image
| Material | Stainless steel |
| Nominal load | 25, 50, 100, 200, 400 kg |
| Limit load | 150 % F.S. |
| Breaking load | 300 % F.S. |
| Supply voltage | Maximum 18 V dc |
| Output | 2 mV/V |
| Output tollerance | 0,1 % F.S. |
| Zero tollerance | 1 % F.S. |
| Linearity | 0,1 % F.S. |
| Hysteresis | 0,05 % F.S. |
| Reapeatability | 0,1 % F.S. |
| Input resistance | 350-360 ohm |
| Output resistance | 350-353 ohm |
| Insulation resistance | >= 2000 Mohm |
| Creep (30 Minutes) | 0,05 % F.S. |
| Thermal compensation | -10 / +40°C (14 / +104°F) |
| Operating temperature | -20 / +70°C (-4 / +158°F) |
| Temperature deviation zero | 0,003 % F.S. / °C |
| Temperature deviation full scale | 0,002 % F.S. / °C |
| Protection class | IP 54 |
| Connection | Panel male connector CR2R-07APNS |
| Standard cable length | Optional: Loose female connector CR2P-07ASNS-10 , connection cable 4 x 0,25 mm2 (length to be defined) |
| Type | CONNECTOR 7P SCC2A-16 |
| Length | 5 m (body lead cell not connected shield) |
| Pin 1 | + OUT |
| Pin 2 | - OUT |
| Pin 3 | NC |
| Pin 4 | NC |
| Pin 5 | NC |
| Pin 6 | + IN |
| Pin 7 | - IN |
General precautions to be followed in the installation and assembly of load cells: